Please use this identifier to cite or link to this item:
https://mnclhd.intersearch.com.au/mnclhdjspui/handle/123456789/491Full metadata record
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Cramp, L. | - |
| dc.contributor.author | Connors, V. | - |
| dc.contributor.author | Wood, M. | - |
| dc.contributor.author | Westhuyzen, J. | - |
| dc.contributor.author | McKay, M | - |
| dc.contributor.author | Greenham, S. | - |
| dc.date.accessioned | 2025-02-03T22:42:37Z | - |
| dc.date.available | 2025-02-03T22:42:37Z | - |
| dc.date.issued | 2016-09 | - |
| dc.identifier.citation | Journal of Medical Radiation Sciences . 2016 Sep;63(3):179-85. | en |
| dc.identifier.uri | https://mnclhd.intersearch.com.au/mnclhdjspui/handle/123456789/491 | - |
| dc.description.abstract | Introduction: Evidence of variations in bladder filling effecting prostate stability and therefore treatment and side-effects is well established with intensity modulated radiation therapy (IMRT). This study aimed to increase bladder volume reproducibility for prostate radiation therapy by implementing a bladder scanning (BS) protocol that could assist patients' bladder filling at computed tomography (CT) simulation and treatment. Methods: Based on a retrospective review of 524 prostate cancer patients, a bladder volume of 250-350 mL was adopted as 'ideal' for achieving planning dose constraints. A prospective cohort study was conducted to assess the clinical utility of measuring patients' bladder volumes at CT simulation using an ultrasound bladder scanner (Verathon 9400 BladderScan(®)). A revised bladder preparation protocol was utilised by a bladder scan group (BS) and a non-BS group followed the standard departmental bladder preparation protocol. Time and volume data for the BS group (n = 17) were compared with the non-BS group (n = 17). Results: The BS cohort had a CT bladder volume range of 221-588 mL; mean 379 mL, SD 125 mL. The non-BS group had a larger range: 184-757 mL; mean 373 mL, SD 160 mL (P = 0.9171). There was a positive correlation between CT volume and BS volume in the BS group (r = 0.797; P = 0.0002) although BS volumes were smaller: range 160-420 mL; mean 251 mL; SD 91 mL; P < 0.0001). The maximum bladder volume receiving 50 Gy (V50) from the BS group was 46.4%, mean 24.5%. The maximum bladder V50 from the non-BS group was 50.9%, mean 27.3% (P = 0.5178). Treatment data from weekly cone beam CT scans were also compared over 6 weeks. They were assessed as being a pass if bladder and bowel requirements were acceptable. The BS group proceeded to treatment on the basis of a pass 92.7% of the time, whereas the pass rate for non-BS group was 75%; difference 17.7% (P < 0.0001). Conclusion: The BS is a useful tool for achieving consistent, appropriately sized bladder volumes in prostate cancer patients. Keywords: Diagnostic imaging; prostate; radiotherapy; ultrasonography; urinary bladder. | en |
| dc.language.iso | en | en |
| dc.subject | Urinary Bladder | en |
| dc.subject | Prostate | en |
| dc.subject | Radiotherapy, Intensity-Modulated | en |
| dc.subject | Ultrasonography | en |
| dc.title | Use of a prospective cohort study in the development of a bladder scanning protocol to assist in bladder filling consistency for prostate cancer patients receiving radiation therapy | en |
| dc.type | Article | en |
| dc.contributor.mnclhdauthor | Cramp, Leah | - |
| dc.contributor.mnclhdauthor | Connors, Vanessa | - |
| dc.contributor.mnclhdauthor | Wood, Maree | - |
| dc.contributor.mnclhdauthor | Westhuyzen, Justin | - |
| dc.contributor.mnclhdauthor | Greenham, Stuart | - |
| Appears in Collections: | Oncology / Cancer Urology | |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
